WATER WELL DESIGN TOOLKIT v1.2.1 |
|
|
|
Contents List
|
|
|
|
|
|
|
|
Form or Calculator name
|
Code
|
Contents
|
|
|
|
Background Information
|
|
|
|
Site information
|
BI/1
|
Details of site owner, location etc.
|
|
|
|
Existing information
|
BI/2
|
Information from existing wells in the area/aquifer.
|
|
|
|
Aquifer information
|
BI/3
|
Information on aquifer type and conditions.
|
|
|
|
Layer information
|
BI/4
|
Lithological descriptions (up to 5 layers).
|
|
|
|
Water chemistry
|
BI/5
|
Chemical analysis data for common constituents influencing well
design.
|
|
|
|
Pumping Rate and Tests
|
BI/6
|
Information on:
|
|
|
|
|
|
a) well yield requirements
|
|
|
|
|
|
b) pumping test results from exploratory borehole(s):
|
|
|
|
|
|
- constant rate aquifer test
|
|
|
|
|
|
- production test (up to 7 steps)
|
|
|
|
|
|
- packer test (up to 5 depth intervals)
|
|
|
|
|
|
c) aquifer properties
|
|
|
|
|
|
d) drawdown components
|
|
|
|
Casing Materials
|
|
|
|
PVC pipe
|
CM/1
|
Calculates weight and collapse strength of PVC casing in metric or
US units.
|
|
|
|
Weight steel
|
CM/2
|
Calculates weight of mild and stainless steel casing in metric or US
units.
|
|
|
|
Collapse strength steel
|
CM/3
|
Calculates collapse strength of mild and stainless steel casing in
metric or US units.
|
|
|
|
Yield point steel
|
CM/4
|
Calculates yield strength of mild and stainless steel casing in
metric or US units.
|
|
|
|
Corrosion/Incrustation Indicator
|
|
|
|
Ryznar Stability Index (RSI)
|
C/1
|
Calculates RSI. Includes charts of S and C values.
|
|
|
|
Costs and Bill of Quantities
|
|
|
|
Pump horsepower
|
CQ/1
|
Calculates water, brake and input horsepower in metric or US units.
|
|
|
|
|
|
Includes pressure to head converter and motor horsepower calculator.
|
|
|
|
Electric pump
|
CQ/2
|
Calculates annual pumping cost, pumping costs per hour and volume of
water of
|
|
|
|
|
|
an electric pump in £, Euros or $.
|
|
|
|
Diesel engine operated pump
|
CQ/3
|
Calculates annual pumping cost, pumping costs per hour and per
volume of water
|
|
|
|
|
|
of a diesel engine driven pump in £, Euros or $. Also calculates
fuel consumption.
|
|
|
|
Capital and operating costs
|
CQ/4
|
Calculates capital cost of a well, monthly and total loan repayment,
total annual
|
|
|
|
|
|
operating costs and cost of water per hour and unit volume with and
without loan.
|
|
|
|
|
|
The loan cost calculator can be used for any combination of loan
amount, fixed
|
|
|
|
|
|
interest rate and loan period.
|
|
|
|
|
|
Water costs can be shown in metric or US units and currency can be
selected from
|
|
|
|
|
|
£, Euros or $.
|
|
|
|
Bill of Quantities
|
CQ/5
|
Bill of Quantities to calculate item and total costs for quotations
or to estimate well
|
|
|
|
|
|
construction costs in metric or US units.
|
|
|
|
|
|
Allows up to 5 different hole, casing and/or screen diameters.
|
|
|
|
Development
|
|
|
|
Air lift pumping
|
D/1
|
Calculates in metric or US units:
|
|
|
|
|
|
- pumping submergence
|
|
|
|
|
|
- minimum pressure required to start air-lift (with
safety factor)
|
|
|
|
|
|
- minimum volume required for selected pumping rate.
|
|
|
|
|
|
Includes Table in metric and US units giving recommended eductor
pipe and air-line
|
|
|
|
|
|
sizes for air-lift pumping at different rates.
|
|
|
|
|
|
Includes charts in metric and US units showing approximate pumping
submergence
|
|
|
|
|
|
for optiumum air-lift efficiency.
|
|
|
|
High velocity jetting
|
D/2
|
Calculates velocity and discharge for high velocity (hydraulic) jet
in metric or US units.
|
|
|
|
Grain Size Analysis for Screen Slot Size and Pack
|
|
|
|
Cumulative percentage
|
GSA/1
|
Calculates cumulative percentage retained or passing for sieve sizes
expressed in
|
|
|
|
|
|
log phi units, mm, '000in, US Standard Sieves and Taylor Equivalent.
|
|
|
|
Grain size data
|
GSA/2
|
Table to enter sieve size in mm or '000 inch and cumulative
percentage retained
|
|
|
|
|
|
or passing.
|
|
|
|
|
|
Data can be entered for up to 15 sieve sizes per table. Data are
plotted automatically
|
|
|
|
|
|
on each chart with a smoothed line through the data.
|
|
|
|
|
|
Six tables are provided allowing up to six distribution curves on
each chart.
|
|
|
|
|
|
Includes converter from metric and US to phi units.
|
|
|
|
metric log chart retained
|
GSA/3a
|
Grain size distribution chart for metric sieve sizes (mm) and
cumulative percentage
|
|
|
|
|
|
retained data from which percentiles can be extracted to GSA/4 or
used to select
|
|
|
|
|
|
the slot size for a natural pack.
|
|
|
|
metric log chart passing
|
GSA/3b
|
Grain size distribution chart for metric sieve sizes (mm) and
cumulative percentage
|
|
|
|
|
|
passing data from which percentiles can be extracted to GSA/4 or
used to select
|
|
|
|
|
|
the slot size for a natural pack.
|
|
|
|
US log chart retained
|
GSA/3c
|
Grain size distribution chart for US units in thousands of an inch
and cumulative
|
|
|
|
|
|
retained data from which percentiles can be extracted to GSA/4 or
used to select
|
|
|
|
|
|
the slot size for a natural pack.
|
|
|
|
log phi chart passing
|
GSA/3d
|
Grain size distribution chart for phi (Ф) sieve sizes and cumulative
percentage
|
|
|
|
|
|
passing data.
|
|
|
|
Percentiles and pack
|
GSA/4
|
Table to enter grain size values as percentage passing or retained
from charts
|
|
|
|
|
|
GSA/3 a to c to show the effective size (Es) and uniformity
co-efficient (Uc) for
|
|
|
|
|
|
each sample and for pack design from P-A ratios.
|
|
|
|
|
|
Pack data are automatically plotted on GSA /3a to 3d.
|
|
|
|
|
|
Subjective sample reliability can be included. Maximum 6 samples.
|
|
|
|
Pack ratio methods
|
GSA/5
|
Calculates key pack grain size diameter values (passing) in mm or
'000 inch using
|
|
|
|
|
a and b
|
different published techniques for pack design. Similar to GSA/4.
|
|
|
|
|
|
Tests for poor sorting and aquifer collapse and calculates passing
or retained pack
|
|
|
|
|
|
grain size diameter values in mm or '000 inch based on Terzaghi's
Rule.
|
|
|
|
Hydraulic Criteria
|
|
|
|
Approach velocity Av
|
HC/1
|
Calculates in metric or US units:
|
|
|
|
|
|
- upper limit of Av based on hydraulic conductivity
(Sichardt and Husiman methods)
|
|
|
|
|
|
or d40 grain size (Gross method)
|
|
|
|
|
|
- screen diameter for given screen length to satisfy
Av based on Sichardt, Huisman
|
|
|
|
|
|
or Gross methods.
|
|
|
|
Reynolds Number Re
|
HC/2
|
Calculates Reynolds Number from d50 grain size in metric or US
units.
|
|
|
|
Uphole velocity Uv
|
HC/3
|
Calculates in metric or US units:
|
|
|
|
|
|
- minimum diameter of casing or screen required to
maintain Uv at <150 cm/s (5 ft/s)
|
|
|
|
|
|
for a chosen discharge rate
|
|
|
|
|
|
- uphole velocity for a chosen casing internal
diameter and discharge rate
|
|
|
|
|
|
- maximum discharge rate for a chosen casing diameter
for Uv of 150 cm/s (5 ft/s).
|
|
|
|
|
|
- uphole head losses.
|
|
|
|
|
|
Includes Table of maximum discharge rates in metric or US units for
selected
|
|
|
|
|
|
diameters of standard-weight casing based on maximum Uv of 150 cm/s
(5 ft/s).
|
|
|
|
Open area, Entrance Velocity
|
HC/4
|
Calculates open area (Ao), entrance velocity (Ev) and transmitting
capacity (Tc) in
|
|
|
|
and Transmitting Capacity of
|
|
metric or US units of slotted or shutter (louver) screen together
with maximum screen
|
|
|
|
slotted and louvered screen
|
|
length for Ev and minimum screen diameter for Uv.
|
|
|
|
|
|
Includes Tables in metric and US units of recommended pump casing
diameters for
|
|
|
|
|
|
different discharge rates and for line shaft pumps and recommended
Ev for different
|
|
|
|
|
|
hydraulic conductivities.
|
|
|
|
Open area, Entrance Velocity
|
HC/5
|
Calculates open area (Ao), entrance velocity (Ev) and transmitting
capacity (Tc) in
|
|
|
|
and Transmitting Capacity of
|
|
metric or US units of continuous slot (wire-wrapped) screen together
with maximum
|
|
|
|
continuous slot screen
|
|
screen length for Ev and minimum screen diameter for Uv.
|
|
|
|
|
|
Includes charts of representative open areas for continuous slot
screen in
|
|
|
|
|
|
metric and US units and Tables of recommended Ev limits for
different K values and
|
|
|
|
|
|
recommended pump casing diameters for different discharge rates and
for line shaft pumps in metric and US units.
|
|
|
|
Recharge Rate and Head
|
|
|
|
Recharge rate and head
|
RR/1
|
Calculates in metric or US units for recharge (injection) wells in
confined or
|
|
|
|
|
|
unconfined aquifer:
|
|
|
|
|
|
- recharge (injection) rate
|
|
|
|
|
|
- maximum allowable positive (recharge) head
|
|
|
|
Steel Screen Materials
|
|
|
|
Collapse continuous slot
|
SSM/1
|
Calculates collapse strength of continuous slot screen in metric or
US units.
|
|
|
|
Yield point continuous slot
|
SSM/2
|
Calculates yield point of continuous slot screen in metric or US
units.
|
|
|
|
Collapse shutter
|
SSM/3
|
Calculates collapse strength of shutter screen in metric or US
units.
|
|
|
|
Yield point shutter
|
SSM/4
|
Calculates yield point of factory slotted or shutter screen in
metric or US units.
|
|
|
|
Volume and Annular Volume
|
|
|
|
Volume and annular volume
|
V/1
|
Calculates in metric or US units:
|
|
|
|
|
|
- volume of casing, screen, drilled hole etc
|
|
|
|
|
|
- annular volume between casing and open hole, etc.
|
|
|
|
Design Summary
|
|
|
|
Results Summary
|
DS/1
|
Summary of the results calculated from the different Topics
(excluding GSA).
|
|
|
|
Units Converter
|
|
|
|
Units converter
|
UC/1
|
Calculator to convert metric to US or US to metric units for some
common hydrogeological parameters
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
© 2008 Well Systems Design (www.waterwelldesign.com)
|
|
|
|